The CERTUSS Economizer increases the degree of generator efficiency and reduces Co2 emissions for generator systems fired by natural gas and #2 oil. As flue gas heat exchanger it uses exhaust gas heat to increase the temperature of the boiler feed water and reduces fuel use by up to 5%.

CERTECON Universal 500 – 600 700 – 850 1000 – 1300 1500 – 1800
A Flue gas inlet Ø internal (inch) 10 12 14 20
B Flue gas outlet Ø external (inch) 7 12 13.5 19.5
C Connecting piece distance (inch) 29 33.5 35.5 37
D Distance floor / connecting piece (inch) 14
E Height (inch) 48.5 52 54.5 57
F Diameter (inch) 31 35.5 40 43
G Water inlet/water outlet PN 40 (DN) 25 25
H Desliming (DN) 15 25
I Dewatering flue gas condensate 3/4’
* Heat output at full load up to (BHP) 0.6 – 0.9 1.2 – 1.5 1.8 – 2.5 2.8 – 4.4
Weight without water (lb) 502 705 853 974
Water capacity (gal) 6.31 11.39 13.63 18.91
Operating overpressure max. (psi) 580 580 580 580
Do you want more information or wish to purchase a Certuss Steam Generator ? Find one of our distributors close to you !